ĐỒNG HỒ ĐO ÁP - BH5220 ECO-A57-K104 - Thiết bị đo áp suất - Labom
PRESSURE GAUGE DN 100 Economic for food/pharmaceutical/biotechnology
Case design: IP 65 with case filling, process connection bottom
Nominal range: 0...6 bar
Overload protected: 1.3 times pointer: with micro adjusting device for zero-point correction case filling: glycerine-water
K104: process connection: sanitary connection with union nut per DIN 11851, DN 40 / PN 40 material stainless steel mat.-no. 1.4404/1.4435 (316L) system filling: Synthetic oil, free of silicon FD1, FDA listed operating temperature range 0...+140°C
Đã bao gồm cả chân ren hàn vào ống.
Constructional design / case
Design:
High quality case with bayonet ring,
material: st.steel mat.-no. 1.4301 (304)
ventilation valve, material: PUR
Nominal size:
NS 63 or NS 100
Degree of protection per EN 60529:
IP 65
Case filling:
Glycerine-water (optional)
Further liquid fillings upon request.
NS 63: screwed
NS 100: pressure connection weld-ed to process connection
System filling:
Synthetic oil, free of silicone FD1, FDA listed, class USDA-H1
Movement:
stainless steel segment
Scale:
Pure aluminium, white with black inscription.
Option: with red marking or with fixed reference pointer Special scale upon request
Pointer:
NS 63: pure aluminium, black
NS 100: pure aluminium, black, with micro adjustment for zero point correction
Weights:
NS 63 without filling: approx. 0.5 kg
NS 100 without filling: approx. 1.0 kg
NS 63 with filling: approx. 0.7 kg
NS 100 with filling: approx. 1.3 kg
Process connection
Design:
With internal diaphragm seal, see order details and product group D5
Material wetted parts
Membran:
See order details
Nominal range
See order details,
further ranges upon request
Overload protection:
Standard: 1.3 times
Accuracy
Accuracy class:
per EN 837-1:
NS 63: class 1.6
NS 100: class 1.0
Temperature influence:
Max. ± 0,4% / 10K of measuring span per EN 837-1
Process-temperature-influence:
depending on active diaphragm diameter
dM 22.6…24 mm ≤ 25 mbar / 10 K
dM 27…30 mm ≤ 20 mbar / 10 K
dM 34…36 mm ≤ 8 mbar / 10 K
dM 40…46 mm ≤ 5 mbar / 10 K
dM 51…58 mm ≤ 2 mbar / 10 K
A detailed calculation of accuracy can be submitted upon request.
Hygienic design
The wetted surfaces made of stainless steel are executed according to EHEDG Doc.8 and ASME BPE SF3 (Code: HY).
We guarantee the following surface roughness values:
Diaphragm foil: Ra ≤ 0.38 µm
Laser welds: Ra ≤ 0.76 µm
Turned parts: Ra ≤ 0.76 µm
Further versions of hygienic design upon request.
Autoclav. design: Autoclavable without case filling, only.
Please remove the Elastomer filling plug before autoclaving.
Temperature ranges
Temperature ranges for the design of the diaphragm seal system (in combination with the pressure transmission fluid FD1):
Ambient without filling: -10…50 °C
Ambient with filling: -10…50 °C
Media without filling: -10…140 °C
Media with filling: -10…140 °C
Adjusted design temperature ranges within the following maximum values are possible on request:
Ambient without filling: -20…60 °C
Ambient with filling: -20…60 °C
Option: Autoclave temperature: 130 °C for 1 hour (without filling)
Storage without filling: -20…60 °C
Storage with filling: -20…60 °C
Extended temperature range (-20...60 °C) optional.
The maximum values can be restricted by the following parameters:
- diaphragm size
- measuring range
- pressure transmission fluid